MERCK 105560 Aluminum TLC plates, RP-18 modified silica gel coated with flourescent indicator F254s. The RP-18 modified silica gel TLC plates come in a quantity of 20 size 5x7.5 cm for thin layer chromatography applications

0 - Yorum Yap
Stok Kodu
105560.0001
Kategori
Havale
3.227,33 TL (%5,00 havale indirimi)
* 362,54 TL den başlayan taksitlerle!!
3.397,19 TL KDV DAHİL
TEKLİF İSTE
*
*
*
*
Description
Catalogue Number 105560
Replaces 5560-4; 5560
Overview RP modified plates serve two purposes: act as a pilot method for HPLC and allow to choose various solvent system for special separations. Our RP-modified silica layers are well suited for many separation challenges that unmodified silica cannot overcome. These layers use aqueous solvent systems to separate extremely non-polar substances and analyze particular polar substances that can adapt to ion-pair chromatography. What’s more, RP-modified silica layers are less dependent on atmospheric humidity. Unlike unmodified silica, RP-phases do not exhibit catalytic activity. This makes them the plates of choice for unstable substance that tend to experience oxidative degradation.
Product Information
HS Code 3822 00 00
Applications
Application Aluminum TLC plates, RP-18 modified silica gel coated with flourescent indicator F254s. The RP-18 modified silica gel TLC plates come in a quantity of 20 size 5x7.5 cm for thin layer chromatography applications.
Safety Information according to GHS
Storage class 10 - 13 Other liquids and solids
Storage and Shipping Information
Storage Storage temperature: no restrictions.
Specifications
Specific surface area (according to BET; 5-Pt. measurement) 480 - 540 m²/g
Pore volume (N₂-isotherm) 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution) 9.5 - 11.5 µm
Layer thickness 150 - 200 µm
Deviation of layer thickness per plate ≤ 30 µm
Chromatographic testings:
A) Cholesterin test
hRf-values
- cholesterin, cholesterin test

28 - 36
B) Steroid test
- methyltestosterone, steroid test 16 - 26
- Reichstein S, steroid test 30 - 40
- hydrocortisone, steroid test 42 - 52
Typical value determined on an activated sheet (120°C, 15 min)
Eluent a) aceton/ water (95/5 v/v)
Eluent b) aceton/ water (60/40 v/v)
Bu ürünün fiyat bilgisi, resim, ürün açıklamalarında ve diğer konularda yetersiz gördüğünüz noktaları öneri formunu kullanarak tarafımıza iletebilirsiniz.
Görüş ve önerileriniz için teşekkür ederiz.
MERCK 105560 Aluminum TLC plates, RP-18 modified silica gel coated with flourescent indicator F254s. The RP-18 modified silica gel TLC plates come in a quantity of 20 size 5x7.5 cm for thin layer chromatography applications TLC Silica gel 60 RP-18 F₂₅₄s Aluminum TLC plates, MERCK 105560.0001 20 units AMBALAJ SENTEZLAB, SENTEZ, merck 105560, 105560, merck Aluminum TLC plates, merck Aluminum TLC plates 105560, Aluminum TLC plates, TLC plates come in a quantity of 20 size 5x7.5 cm for thin layer chromatography applications 105560.0001
MERCK 105560 Aluminum TLC plates, RP-18 modified silica gel coated with flourescent indicator F254s. The RP-18 modified silica gel TLC plates come in a quantity of 20 size 5x7.5 cm for thin layer chromatography applications

Tavsiye Et

*
*
*
IdeaSoft® | E-Ticaret paketleri ile hazırlanmıştır.